2600VA line-interactive UPS for server, network and telecommunications equipment. 2U rackmount form factor. Corrects brownouts and overvoltages from 79V to 147V. Sine wave output. Maintains battery-derived AC output during blackouts and severe voltage fluctuations. Expandable runtime with optional external battery packs. 9 output receptacles. NEMA 5-20P input plug; NEMA L5-30P replacement plug included. Network-grade AC surge and noise suppression. Network management interfaces include 2 USB ports, 2 DB9 serial ports and SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 5 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated 3-bank switched PDU. 3-stage metered current monitoring and battery charge LEDs. Utility power and voltage regulation LEDs. Audible alarm. Self-test. 4-post rack mounting accessories included; 2-9USTAND and 2POSTRMKITWM accessories available. Field-replaceable, hot-swappable internal batteries and battery packs. Attractive all-black color scheme. 2-year warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.
Plug/Connector Type:
NEMA 5-20P
Receptacles:
4 x NEMA 5-15R
Switching Time:
4 ms
Load Capacity:
2.60 kVA/2.10 kW
Input Voltage:
110 V AC
Input Voltage Range:
120 V AC Single-phase
Output Voltage:
120 V AC Single-phase
Frequency:
60 Hz
Waveform Type:
Sine Wave
Filtering:
EMI / RFI
Status Indicators:
5 front panel LEDs - Green POWER LED, Green VOLTAGE CORRECTION LED, 3 color BATTERY CHARGE LED, 3 color OUTPUT LOAD LED, red BATTERY WARNING LED
Interfaces/Ports:
2 x USB
Modular Slots:
1 x Communications Slot
Batteries:
Sealed Lead Acid User Replaceable Hot-swappable
Backup/Run Time:
0.30 Hour 1.30 kW Half Load
Battery Life:
26297.44 Hour to 52594.88 Hour
Battery Recharge Time:
4 Hour
Form Factor:
2U Rack-mountable
Power Cord/Cable:
10 ft
Package Contents:
SmartPro 2600RM2U UPSSMART2600RM2U UPS System, PowerAlert Software and cabling, Mounting hardware, Warranty information, Instruction manual
Additional Information:
2600VA / 2100 watt output power capacity compatible with North American 120V / 60Hz power 2U rack/tower UPS installs in standard 19 inch rack enclosures with an installed depth of only 19 inches Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges Line interactive Automatic Voltage Regulation (AVR) corrects inputs from 79-147VAC back to usable 120V levels without consuming battery power Dual boost AVR circuits boost undervoltages by 14% or 24% depending on the severity and reduces overvoltages by 12% Network interfaces support simultaneous communications via 2 USB, 2 DB9 serial and SNMPWEBCARD slot Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, internal UPS temperature, AC line frequency, timed inverter shutoff, activate self-test and load bank output power control Built in Emergency Power Off (EPO) interface with cable Sine wave output in AC and battery modes Expandable runtime with optional battery packs - BP48V24-2U (limit 1) and BP48V60RT-3U (multi-pack compatible) Half load runtime of 18 minutes with internal batteries, Add 1 BP48V24-2U for 49 minutes or 1 BP48V60RT-3U for 107 minutes (1300VA / 1050 watts) Full load runtime of 6 minutes with standard internal batteries, Add 1 BP48V24-2U for 22 minutes (2600VA / 2100 watts) Includes 9 output receptacles arranged in 3 load banks (4 NEMA 5-15R / 4 NEMA 5-15/20R / 1 NEMA L5-20R) Ships with NEMA 5-20P input plug, user installable NEMA L5-30P replacement plug included Integrated 3 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices 3 stage metered LEDs offer current monitoring and battery charge level Mains power and voltage regulation LEDs offer at-a-glance power status information Front panel switches support self-test and alarm cancel functions Included UPSRMRII adjustable mounting rails support installation in 19 inch racks with a front-to-rear depth of 23.5 and 36.5 inches (add a 2nd UPSRMRII accessory to extend the reach to 35.25 to 49.5 inches) UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required Supports 2 post rackmount installation with optional 2POSTRMKIT accessory Supports upright tower placement with optional 2-9USTAND accessory UL (USA), cUL (Canada), NOM (Mexico), FCC Class A (Emissions) listed 2 year manufacturer's product warranty, $250,000 Ultimate Lifetime Insurance
System Requirements:
TYPICAL APPLICATIONS: Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection. Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems.